RFQ Amendment (Questions) 13 MAR 26 Repair Services - Chiller Plant Skid 1 & 2 Pump
VETERANS AFFAIRS, DEPARTMENT OF · NAICS 333415 · SDVOSBC · Deadline 2026-03-13T10:00:00-05:00
Solicitation description
Amendment 00001 provides responses to questions for Solicitation Number 36C25626Q0449 and extends the due date of this solicitation. 1. Photos of the pumps/motors showing piping arrangement, electrical connection, and nameplate data. Are VFDs required? Is there any BAS connections or interlocks for the pumping system? ANS: The pics are attached to the email for this project. VFD's are required but not being replaced. No BAS connections needed. 2. Electrical for the Motors: HP, Voltage, Amperage and disconnecting means and locations. ANS: The information are located in the pics attached to the email. Electrical is all on name plate of pumps in pics 3. Pump capacity information: Flow Rate in GPM, & Pumping Head. ANS: The information are located in the pics attached to the email. Flow rate and GPM are on name plates in pics 4. What type of insulation is installed and thickness? ANS: The insulation is wrapped fiberglass insulation 2" thick 5. Is pump an End Suction, Double Suction, or In Line type Pump. ANS: See pics of pumps for the alignment for inlet and outlet 6. What is the pipe size for the Taco Triple Duty Valves to be installed. ANS: The piping is 12" for chiller 1 and 10" for chiller 2 Clarify the questions come from the scope: "The Contractor shall provide all tools, shipping, delivery, personnel, transportation, demolition, removal of old equipment, installation of new equipment, modifications to existing piping, to deliver and install the necessary equipment for repairing Chillers 1, and 2 ANS: The contractor must install both pump/motor for each chiller 1&2 and triple duty valve for both chillers. 2. The scope is to provide regular system health checks, preventative/routine maintenance, repairs, onsite training, and access to a technical support team in support of two industrial chillers and their subcomponents which consist of, but not limited to: magnetic drive pumps, piping, electrical connections, regulator valves, pneumatic actuators, gauges and indicators, heat exchangers, AC drives, and input modules. " ANS: The contractor after installation must verify the installation correct with functional for the 2 chillers pump/motors and triple duty valve.
Similar opportunities
Other open SAM.gov opportunities under the same NAICS, prioritizing the same buying agency.
| Title | Agency | Est. value | Basis |
|---|---|---|---|
| Walk-In Cooler/Freezer and Hood - Delivery and Installation | VETERANS AFFAIRS, DEPARTMENT OF | $1.4M | same agency naics |
| Pyxis Equipment for Bay Pines and Lee County | VETERANS AFFAIRS, DEPARTMENT OF | $0.9M | same agency naics |
| Lab Fridges & Freezers - IC 07/01/2026-09/15/2026 | VETERANS AFFAIRS, DEPARTMENT OF | $0.2M | same agency naics |
| NEW < SAT | NFS Freezer Replacement | VETERANS AFFAIRS, DEPARTMENT OF | $0.1M | same agency naics |
| Chill Water Pump VFD | VETERANS AFFAIRS, DEPARTMENT OF | $0.0M | same agency naics |
| Laboratory Refrigerator & Freezers (VA-26-00035725) | VETERANS AFFAIRS, DEPARTMENT OF | $0.0M | same agency naics |
| Salt Lake City Patient Fridge Freezers | VETERANS AFFAIRS, DEPARTMENT OF | - | same agency naics |
| Request for Information After Hours Emergency Service... | VETERANS AFFAIRS, DEPARTMENT OF | - | same agency naics |
Data this profile does NOT cover
- No likely incumbent surfaced; the solicitation number did not prefix-match any award in the FPDSAward window.
- No FPDSAward rows for NAICS 333415 in the trailing 12 months; vendor concentration unavailable.